Fortifying data centers: the crucial role of IT Shielding

Introducing our state-of-the-art modular panels designed to fortify data centers against numerous risks, including fire, water damage, and more. Engineered with cutting-edge materials, the modular panels serve as a robust defense system, safeguarding critical infrastructure and invaluable data.

First and foremost, it is important to comprehensively evaluate the risks to which the facility is exposed. This evaluation serves as the cornerstone for determining the appropriate level of protection required to ensure high availability.

The goal is to minimize vulnerabilities and enhance resilience in the face of potential disruptions.

At the outset of the risk assessment, potential threats such as fire, water damage, physical intrusion, electromagnetic interference, and environmental hazards are identified. Each threat must be meticulously evaluated in terms of their likelihood of occurrence and potential impact on availability.

ISO/IEC 27001

Information Security Management, a world renowned standard

According to ISO/IEC 27001 the definition of physical security for data center corresponds to the creation of barriers in order to avoid, or reduce, numerous risks. Such as fire, flooding, explosion, landslide, storm, lightning, EMC, sabotage, and others.

IT Shielding are tested and certified solutions that boosts IT security and aggregate resilience for business continuity.

Potential physical threats to IT availability

Recognizing the risks is the initial step toward addressing them effectively

According to the recommendations of ISO/IEC 27001, it is important to mitigate pothential threats to data center physicals security. The enumerated risks are:

Edgefy: Proteção contra incêndio. IT Shielding e medidas de segurança contra incêndios em data centers.

Fire and its derivatives;

Fire poses one of the most dreaded threats, not only to IT equipment and infrastructure, but also, and most crucially, to the data itself. Even in minor incidents, the potential for devastating damage to IT assets is significant once flames take hold.

Furthermore, the dangers extend beyond mere flames. Elevated temperatures, humidity levels, and corrosive gases present additional risks. If temperatures exceed 75°C or humidity levels surpass 85%, data loss becomes a real possibility. Additionally, in the event of a major fire, falling debris and the use of extinguishing water can result in incalculable damage.

Edgefy: Proteção contra água. IT Shielding e medidas de segurança contra danos a equipamentos de TI em data centers e locais vulneráveis a inundações e umidade.

Water;

IT equipment should never be exposed to water or high humidity levels. Therefore, caution is imperative, particularly in indoor data centers, where the risk of faulty water installations is significant. Similarly, outdoor applications present their own set of challenges, such as the threat of torrential downpours.

Moreover, the risk of flooding must also be carefully considered. Conducting a thorough risk analysis to assess the historical occurrence of flooding at the site is highly recommended.

Edgefy: Proteção contra poeira. IT Shielding e medidas de segurança para equipamentos de TI em ambientes onde altos níveis de poeira podem representar riscos significativos.

Dust;

Dust is not typically a concern in standard office environments, where extraction filters can effectively manage ambient dust levels. However, in production sites or mining companies, the situation can change dramatically. The significant volume of dust produced in such environments can overwhelm extraction systems, posing significant risks to IT equipment.

Edgefy: Proteção contra acesso não autorizado. IT Shielding e medidas de segurança para proteger dados valiosos contra sabotagem, roubo e métodos de invasão, garantindo a segurança em ambientes de TI.

Unauthorized acess and sabotage;

Attempts to sabotage, steal, or destroy your data may occur. Given that data is one of the most valuable assets of an organization, keeping intruders out is crucial. Burglars typically employ various methods to gain access, including the use of tools, firearms, explosives, and electromagnetic interference (EMC).

IT Shielding

Edgefy's modular IT Shielding is rigorously tested and certified products. Our offerings feature two levels of protection: Vault and Safe, each addressing specific risk vectors differently.

ABNT NBR 10636 | Safe IT Shielding

ABNT NBR 15247 | Vault IT Shielding

+ 150

racks

+ 1,82

MW

III

Tier

1,4

PUE

Case SERPRO

Block building, modular, alta capacidade de processamento, escalável, infraestrutura de energia eficiente

Certificação NBR/ABNT 10636

O novo data center modular do SERPRO (Serviço Federal de Processamento de Dados) possui certificação conforme a norma NBR/ABNT 10636, atendendo aos critérios estabelecidos para garantir um ambiente protegido contra diversos riscos.

Tier III

Além de uma infraestrutura física robusta e resiliente, o Data Center possui certificação Tier III pelo Uptime Institute. Dessa forma é possível realizar manutenções concorrentes sem impactar no serviço para garantir a disponibilidade.

Edgefy: Case SERPRO: usina de geradores

PUE 1,4

O data center modular do SERPRO tem um PUE de 1,4 que é altamente eficiente, consumindo apenas 40% da energia total para operações de suporte, como climatização. Esse desempenho reflete um design otimizado e sustentável, garantindo economia e alta performance operacional.

Edgefy: Data center modular SERPRO: Tela de gestão do ar-condicionado

Planta baixa simplificada

O data center modular do SERPRO é formado por múltiplos containers e oferece uma infraestrutura completa e segmentada, garantindo eficiência e segurança. Com áreas separadas para front desk, NOC (Centro de Operações de Rede), data halls, salas elétricas, e uma usina de geradores, ele permite maior controle e gestão operacional. Essa estrutura modular também proporciona escalabilidade, permitindo que novos containers sejam integrados conforme a demanda cresce, além de oferecer alta resiliência por meio da segregação de sistemas críticos e operacionais.

Gostaria de saber mais sobre o Edgefy?

Ao clicar acima, você concorda com as Políticas de privacidade e cookies deste site.

Usamos cookies para garantir a melhor experiência em nosso site. Se você continuar navegando, assumiremos que está de acordo com a nossa política de privacidade e cookies.